!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Files updated for 2014
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!




PS ring.

-----------------------------------------------------------------------------

There are four types of optics:

LHC EXTRACTION. Protons 26 GeV/c
-LHC_Extraction_NoExtractElem_for_OP_group.madx.      User:  MD3
-LHC_Extraction_WithExtractElem_for_OP_group.madx.    User:  MD3

AD EXTRACTION. Protons 26 GeV/c
-AD_Extraction_WithExtractElem_for_OP_group.madx.     User:  MD3

Slow extraction to the EAST HALL. Line FT61. Protons 24 GeV/c
-24GeVc_Extraction_NoExtractElem_for_OP_group.madx.   User:  EASTA
-24GeVc_Extraction_WithExtractElem_for_OP_group.madx. User:  EASTA
-24GeVc_for_OP_group.madx.                            User:  EASTA

nTOF 20 GeV/c :
-nTOF_20GeVc_NoExtractElem_for_OP_group.madx.         User:  TSTPS
-nTOF_20GeVc_WithExtractElem_for_OP_group.madx.       User:  TSTPS

CT extraction. Protons 14 GeV/c
-14GeVc_NoExtractElem_for_OP_group.madx.              User:  TSTPS
-14GeVc_WithExtractElem_for_OP_group.madx.            User:  TSTPS

MTE extraction. Protons 14 GeV/c
-14GeVc_MTE_WithExtractElem_for_OP_group.madx.        User:  TSTPS

10 GeV/c
-10GeVc_for_OP_group.madx.                            User:  TSTPS

3.5 GeV/c
-3.5GeVc_for_OP_group.madx.                           User:  TSTPS

Proton injection. 2.12 GeV/c
-Injection_for_OP_group.madx.                         Users: MDPRO and TSTPS




-----------------------------------------------------------------------------

Further information:
http://cern-accelerators-optics.web.cern.ch/cern-accelerators-optics/PSoptics/defaultPS.htm
The raw measurements that are the basis of the PFWs are in Matrix_meas {see last line on web page}

-----------------------------------------------------------------------------

Please excecute the madx files in directory madx, with the command, e.g. :

 >madx < 3.5GeVc_for_OP_group.madx

 All the madx files calls PTC

-----------------------------------------------------------------------------

 The structure of the files are:
    <>.ele   Element  files. The definition of the elements/equipments
    <>.seq   Sequence files. The layout of the elements
    <>.str   Strength files. The strength or currents of the elements
    <>.madx  MADX     files. Set-up of a particular optics.


 Display plot:  >gv ./output/3.5GeVc01.eps


 NB! The extension for the MADX files is <>.madx and not <>.mad.
     The reason is that when the files are read via the web, the
     .mad extension is taken as Microsoft Access module and not
     as a text file. By using .madx extension, the files are inter-
     preted as text files on the web.

[ICO]NameLast modifiedSizeDescription

[PARENTDIR]Parent Directory  -  
[TXT]GammaTransCurrents.txt2015-03-25 13:28 37K 
[DIR]aperture/2016-05-25 09:41 -  
[DIR]cmd/2015-03-30 22:55 -  
[DIR]elements/2015-03-30 22:55 -  
[DIR]for_OP_group/2015-11-18 12:26 -  
[DIR]madx/2015-11-18 12:25 -  
[DIR]output/2015-11-18 12:26 -  
[DIR]sequence/2015-03-30 22:55 -  
[DIR]strength/2015-03-30 22:55 -