USER MANUAL
SYNOPSIS
PTC_SETKNOBVALUE,
elementname = [s, none] ,
kn = [i, {-1}],
ks = [i, {-1}],
value = [r] ;
Description
With this command the user set a given knob value. In its effect all the values in
- the twiss table used by the last ptc_twiss command
- the columns specified with ptc_select, parametric=true;
are reevaluated using the buffered parametric results.
The parameters of the command basically contains the fields that allow to identify uniquely the knob and
the value to be set.
Example
dog leg chicane :
strength of dipol field component in quads is matched to obtain required R56 value.
Command parameters and switches
- elementname
-
string in range format,
Specifies name of the element containing the knob to be set.
- kn,ks
-
list of integers,
Defines the knob
- value
-
real, default 0, if value explicitly not specified then 0
Specifies the value the knob is set to.