Before imperfections can be listed,
the elements to be printed must be selected by a
SELECT command.
Then a table of errors assigned to these elements can be printed
by the command
EPRINT,FILE=string,ALIGN=logical,FIELD=logical,ORDER=integer,RADIUS=real;
The command has the following attributes:
- FILE
-
The file to receive the output.
- ALIGN
-
If true, the alignment errors are printed.
- FIELD
-
If true, the field errors are printed.
- ORDER
-
The order used for normalizing, like on EFIELD and
EFCOMP.
- RADIUS
-
The radius used for normalizing, like on EFIELD and
EFCOMP.
MAD User Guide, http://wwwslap.cern.ch/mad/