DUNE DAQ Prototype
Introduction
This is the new wiki for DAQ at the Neutrino Platform. You will find useful links (some of them still referring to NP04) and basic instructions to run the DAQ.
Useful links for everyone
- NP04 E-Logbook (for access subscribe to e-group np04-t0comp-users, for notifications subscribe to pdsp-elog-messages here)
- NP02 E-Logbook (for access subscribe to e-group np02-t0comp-users, for notifications subscribe to pddp-elog-messages here)
- VD coldbox E-Logbook (for access subscribe to e-group np-vd-coldbox-elog, for notifications subscribe to np-vd-coldbox-elog-messages here)
- The DAQ software is hosted here and documentation for it can be found here.
Basic Guide for taking data with the DAQ
For experts
Useful links
Timing
Timing masters
Test stand |
Hardware |
Firmware |
IPBus ID |
IP address |
Address map |
UID/MAC |
JTAG pc |
JTAG Cable Shortcut |
Full JTAG Cable ID |
Vertical drift coldbox (VDC) |
NP04-TLU-01 |
Boreas @ 62.5 MHz v7.0.0 |
BOREAS_TLU_NP04_NOCDR |
10.73.137.84 |
v7xx/boreas_tlu/top_tlu.xml |
54:10:ec:bb:94:26 |
np04-onl-003 |
53FA |
Digilent/25163300153FA |
NP04 (Old firmware) |
PC059 |
Fanout @ 62.5 MHz v6.4.0 |
PROD_FANOUT_0_CH |
192.168.200.65 |
v642/fanout_pc059/top.xml |
d8:80:39:d9:8a:e9 |
np04-onl-003 |
4E7A |
Digilent/2516330014E7A |
NP02 SSPs (Old firmware) |
PC059 |
Fanout @ 62.5 MHz v6.4.0 |
PROD_FANOUT_2_CH |
192.168.200.67 |
v642/fanout_pc059/top.xml |
d8:80:39:d9:24:91 |
np04-onl-003 |
4E4A |
Digilent/2516330014E4A |
NP04 (New firmware) |
PC059 |
Master @ 62.5 MHz v7.0.0 |
PROD_MST_PC059_1_CH |
192.168.200.66 |
v7xx/master_pc059/top_pc059.xml |
d8:80:39:d9:24:98 |
np04-onl-003 |
4D9A |
Digilent/2516330014D9A |
Horizontal drift coldbox |
PC059 |
Master @ 62.5 MHz v7.0.0 |
TERTIARY_NOCDR_CH |
192.168.200.32 |
v7xx/master_pc059/top_pc059.xml |
d8:80:39:d9:80:cf |
np04-onl-004 |
F4CB |
Digilent/210299A1F4CB |
Timing master initialisation sequence
Example for
PROD_MASTER_VDC:
pdtbutler io PROD_MASTER_VDC reset
pdtbutler mst PROD_MASTER_VDC synctime
pdtbutler mst PROD_MASTER_VDC part 0 configure --no-spill-gate
pdtbutler mst PROD_MASTER_VDC align apply-delay 0 0 0 --force
Readout
This section is a collection of Readout troubleshooting guidelines.
Readout Unit reboot
At the moment, the 100Gb NICs are not automatically configured to be usable for DAQ operations. After a readout unit is rebooted, one needs to execute the following script as root:
sudo /opt/setup-100g-vfio.sh
Errors related to the sriov plugins are known and not an issue. So one can safely ignore errors like this:
Restarting sriov plugins
ctr: no running task found: task 2ed27287f677272ad61300a47c2e0ec5caeb45ce4ad7858f7286cb41efdff864 not found: not found
Old Links
(Linked here just in case they're useful, but they probably aren't.)
--
WesleyRobertKetchum - 2024-02-27