Next: Beam Position Monitors
Up: Physical Elements and Markers
Previous: RF Cavities
  Contents
  Index
Electrostatic Separators
An ELSEPARATOR (electrostatic separator) has three real
attributes:
label:ELSEPARATOR,TYPE=string,APERTURE=real-vector,L=real,EX=real,EY=real;
- L
-
The length of the separator (default: 0 m).
- EX
-
The horizontal electric field strength (default: 0 MV/m).
A positive field increases for positive particles.
- EY
-
The vertical electric field strength (default: 0 MV/m).
A positive field increases for positive particles.
A ELSEPARATOR requires the particle momentum P
and its charge CHARGE to be set in the relevant
BEAM command before any calculations are performed.
Example:
BEAM,PARTICLE=POSITRON,PC=46.0;
SEP:ELSEPARATOR,L=5.0,E=0.5;
The reference system for a separator is a
Cartesian coordinate system.
MAD User Guide, http://wwwslap.cern.ch/mad/