Hardware for the HV system
The system is powered by 180 HV channels, 90 positive and 90 negative, by 15
A1534N boards and 15
A1534P boards,
hosted in 2 SY1527 power supplies.
In March 2006 CAEN delivered the 2 Power Supplies and almost all the boards.
These are the results of the tests performed on all boards.
CAEN Power Supplies |
Power Supply |
name |
Rack |
Alias (proposal) |
Remarks |
SY1527 |
alitofcae000 |
CR4-Z02 |
alitofsyhvn FIXME |
hosting negative boards |
SY1527 |
alitofcae000 |
CR4-Z03 |
alitofsyhvp FIXME |
hosting positive boards |
SY1527LC |
alitofcae000 |
I03 |
alitofsylv?? FIXME |
hosting 3 branch controllers |
SY1527LC |
alitofcae000 |
I32 |
alitofsylv?? FIXME |
hosting 3 branch controllers |
SY1527LC |
alitofcae000 |
O03 |
alitofsylv?? FIXME |
hosting 3 branch controllers |
SY1527LC |
alitofcae000 |
O32 |
alitofsylv?? FIXME |
hosting 3 branch controllers |
HV Positive Boards |
|
HV Board |
Serial n. |
Test 2006/04/04-05 |
Test 2006/06/02 |
Remarks |
Remarks Nov.06 |
1 |
A1534P |
20 |
not tested, used in lab 167 |
Ok |
prototype, refurbished by CAEN |
BAD . |
2 |
A1534P |
24 |
Ok |
Ok |
-- |
BAD (ch 0-1 switch off) |
3 |
A1534P |
25 |
Ok |
Ok |
-- |
-- |
4 |
A1534P |
26 |
Ok, OvC /UnV in Ch02 once |
Ok |
-- |
BAD |
5 |
A1534P |
27 |
Ch01,Ch05 > 1A when OFF, Ch02 broken |
Ok |
repared by CAEN in May'06 |
-- |
6 |
A1534P |
30 |
-- |
-- |
-- |
NEW: Under test |
7 |
A1534P |
31 |
Burned channels |
Ok |
repared by CAEN, May'06 |
Under test (again) |
8 |
A1534P |
32 |
Ok |
Ext-Disabled |
repaired by CAEN, 9-Aug'06 |
-- |
9 |
A1534P |
33 |
HVMax not calibrated |
Ok |
HVMax checked by CAEN, May'06 |
-- |
10 |
A1534P |
34 |
HVMax not calibrated |
Ok |
HVMax checked by CAEN, May'06 |
-- |
11 |
A1534P |
35 |
HVMax not calibrated |
Ok |
HVMax checked by CAEN, May'06 |
-- |
12 |
A1534P |
36 |
HVMax not calibrated |
Ok |
HVMax checked by CAEN, May'06 |
-- |
13 |
A1534P |
37 |
Ch03 burned |
Ok |
repared by CAEN, May'06 |
-- |
14 |
A1534P |
38 |
Ok |
Ok |
-- |
-- |
15 |
A1534P |
39 |
Ok |
Ok |
-- |
-- |
16 |
A1534P |
41 |
Ok, Ch00 UnV /OvC once |
Ok |
-- |
-- |
17 |
A1534P |
42 |
-- |
-- |
-- |
NEW: Under test |
18 |
A1534P |
43 |
-- |
-- |
-- |
BAD |
|
|
|
HV Negative Boards |
|
HV Board |
Serial n. |
Test 2006/04/04-05 |
Test 2006/06/02 |
Remarks |
Remarks Nov.06 |
1 |
A1534N |
21 |
possible spikes on Ch00 |
Ok |
-- |
-- |
2 |
A1534N |
22 |
Ok |
Ok |
-- |
-- |
3 |
A1534N |
23 |
-- |
-- |
-- |
NEW: Under test |
4 |
A1534N |
24 |
Ok |
Ok |
-- |
-- |
5 |
A1534N |
25 |
-- |
-- |
-- |
NEW: Under test |
6 |
A1534N |
26 |
Ok |
Ok |
-- |
-- |
7 |
A1534N |
27 |
Ok |
Ok |
-- |
-- |
8 |
A1534N |
28 |
Ok |
Ok |
-- |
-- |
9 |
A1534N |
29 |
Ok |
Ok |
-- |
-- |
10 |
A1534N |
40 |
-- |
-- |
-- |
BAD |
11 |
A1534N |
41 |
-- |
-- |
-- |
NEW: Under test |
12 |
A1534N |
42 |
-- |
-- |
-- |
NEW: Under test |
13 |
A1534N |
43 |
HVMax not calibrated |
Ok |
-- |
-- |
14 |
A1534N |
44 |
HVMax not calibrated |
Ok |
-- |
-- |
15 |
A1534N |
45 |
HVMax not calibrated |
Ok |
-- |
-- |
16 |
A1534P |
46 |
Ext-Dis |
Ok |
repared by CAEN, May'06 |
-- |
17 |
A1534N |
47 |
Ok |
Ok |
-- |
-- |
18 |
A1534N |
49 |
Ok |
-- |
used for cosmics since 2006/04/05 |
-- |
19 |
A1534N |
50 |
HVMax not calibrated |
Ok |
-- |
-- |
15 KV Positive Boards |
HV Board |
Serial n. |
Remarks |
A1526P |
49 |
Ok, 2006/04/04 |
A1526P |
50 |
Ok, 2006/04/04 |
|
|
15 KV Negative Boards |
HV Board |
Serial n. |
Remarks |
A1526N |
54 |
Ok, 2006/04/04 |
A1526N |
56 |
Ok, 2006/04/04 |
20-Feb-2007
A1534N 21 and
A1534P 32 given back to CAEN (S. Petrucci).
8-Mar-2007
Returned by Di Maio.
Test of HV distribution boxes
On 29/08/2006 (first test at 8 kV) and 31/08/2006 (second test at 12 kV) 15 distribution boxes have been tested.
Results:
- 10 boxes OK (tested with 8 kV and 12 kV)
- 5 boxes NOT_OK
- 4 boxes failed the first test (OverCurrent around 5000-6000 V)
- 1 box succeded the test at 8 kV but failed the test at 12 kV (and now it's failing also at 5000-6000 kV)
Test Procedure:
Testing the internal connections:
- GND connections: the 5 external shells of the unipolar cables and the central pin of the tripolar cable are connected
- Hot cable: the resistance between the single pin of the tripolar connector and the internal pin of the unipolar connectors is 1 MΩ
- the resistance between the internal pins of the unipolar connectors is 2 MΩ
- the "cold contact" should be connected to the external shield (:?: CHECK)
Test at 8000 V:
- a tripolar cable conects the box to the A1534 board, and the channel is switched on with V0=8000 V
- the box is kept in High Voltage for a few minutes.
Test at 12000 V:
- a metallic box has being built to permit the connection from the A1526 board (unipolar connectors) to the red box (tripolar connectors)
Location:
- all the material is now in room 10, blg 29.
2. Test of HV distribution boxes
On 14/09/2006 CPE delivered 9 boxes, without any painting.
Results:
- 3 boxes OK at 12 kV (we tested one at 13 kV getting sparks, so we decided not to test the other two at 13).
- 6 boxes NOT OK
The 6 have been dismantled to check if the origin of the sparks was visible, without success.
All the remaining boxes and the connection boxes (thanks to Dimitri for helping preparing them) are in Room 10.