AtlasPublicTopicHeader.png

Combined Muon Performance Public Plots from Cosmic-Ray Data

Introduction

The combined muon performance plots below are approved to be shown by ATLAS speakers at conferences and similar events.

Please do not add figures on your own.
Contact the the muon combined performance coordinators (atlas-perf-muons-conveners@cernNOSPAMPLEASE.ch) in case of questions and/or suggestions.

Plots from first reprocessing of cosmics 2008 data

The plots show, on cosmic data from autumn 2008, the comparison between quantities reconstructed for inner detector tracks and for matching muon spectrometer ones. The observed differences are in agreement with the expected multiple scattering and energy loss in the calorimeters and are well reproduced by the Monte Carlo simulation. No correction has been yet applied for the relative alignment of the two subdetectors, which appears to be already quite good.

The plots were obtained using 18k data events from ATLAS combined cosmic run 91890, taken with both solenoid and toroid fields on. These events, produced by the December 2008 re-processing at Tier1's, were pre-selected requiring a reconstructed track in the Inner Detector (ID). Simulated events use the latest samples available at the time, made with release 14.4.0. One of the main improvements with respect to previous simulations was the use of the Xe-gas mixture for the transition radiation tracker (TRT) and an updated detector description geometry. The relevant parts of the reconstruction chain were re-run with release 14.5.0.5, with a special fix for an incorrect drift function also used for the simulated data. In addition, one RPC sector (6) was masked in simulation, corresponding to the real detector configuration in the run analysed.

The following event selection was applied in order to emulate the stream and trigger configuration used:

  • At least one track reconstructed in the ID.
  • At least one combined ID-MS reconstructed track with 3 or more RPC Phi hits.

After all these cuts, the number of events in the analysis is:

  • Real data: 4.8k events (initially 18k)
  • Simulated data: 6k events (initially 10k).

Tracks reconstructed by MOORE and CTB trackers in the MS and ID respectively were used for this analysis. No global ID-MS alignment corrections were applied in the reconstruction.

Next, the track parameters at perigee are compared between MS and ID standalone reconstructions. Except the momentum, MS track parameters are extrapolated to the beam axis (taking into account the energy loss in the calorimeters) in order to allow for comparisons. Next, the track parameters at perigee are compared between MS and ID standalone reconstructions. In order to compare Theta0 and z0 parameters, ID tracks are required to have Silicon hits.

An internal note with some more technical details on the reconstruction is available, for ATLAS members only, at ATL-COM-PHYS-2009-074.

Correlation between Muon Spectrometer (MS) and Inner Detector (ID) track parameters [Run 91890]: Phi0 correlation.

The good correlation observed between parameters measured in the MS and ID shows that both sub-detectors are well synchronized.

eps version

Phi0.

Correlation between Muon Spectrometer (MS) and Inner Detector (ID) track parameters [Run 91890]: Theta0 correlation.

The good correlation observed between parameters measured in the MS and ID shows that both sub-detectors are well synchronized.

eps version

Theta0.
Difference between Muon Spectrometer (MS) and Inner Detector (ID) standalone reconstruction [Data/MC comparisons]:

Phi0 parameter.

The differences between the track parameters measured in the MS and the ID gives an idea about how well both sub-detectors are mechanically aligned. The agreement data/MC is fairly good.

eps version


Diff_phi0.
Difference between Muon Spectrometer (MS) and Inner Detector (ID) standalone reconstruction [Data/MC comparisons]:

Theta0 parameter.

The differences between the track parameters measured in the MS and the ID gives an idea about how well both sub-detectors are mechanically aligned. The agreement data/MC is fairly good.

eps version


Diff_theta0.
Difference between Muon Spectrometer (MS) and Inner Detector (ID) standalone reconstruction [Data/MC comparisons]:

d0 parameter.

The differences between the track parameters measured in the MS and the ID (QoverP distribution available for the Inner Detector approved plots page) gives an idea about how well both sub-detectors are mechanically aligned. The agreement data/MC is fairly good.

eps version


Diff_d0.
Difference between Muon Spectrometer (MS) and Inner Detector (ID) standalone reconstruction [Data/MC comparisons]:

z0 parameter.

The differences between the track parameters measured in the MS and the ID gives an idea about how well both sub-detectors are mechanically aligned. The agreement data/MC is fairly good, within 4mm.

eps version


Diff_z0.
By taking the difference in the momentum measured in the ID and MS, one can study the energy loss in the calorimeters. The plot shows this difference between ID and bottom MS tracks. A mean value of about 3 GeV is observed for both data and MC.

eps version


Diff_MomentumBottom.

Plots from fast reprocessing of cosmics June-July 2009 data

We compare the momenta measured by the tracking devices (inner detector and muon spectrometer) with the energy measured by the calorimeters (LArEM and Tile) and the energy deposited around muon tracks for an isolated muon sample. Cosmic-ray data from june 2009 was used, from the official ATLAS processing. these plots were approved on 15/1/2010.

Calorimetric isolation: sum of transverse energy around muon tracks for cones of dR = 0.2, 0.3 and 0.4 (eps file)


Isolation

Momentum difference between Inner Detector and Muon Spectrometer tracks compared with the energy loss measured in the calorimeters, and a parametrization of the energy loss in the inert material. (eps file)


Muon energy loss
Subtraction of the momentum difference between Inner Detector and Muon Spectrometer tracks, and energy loss measured in the calorimeters, corrected by a parametrization of the energy loss in the inert material, for two momentum ranges: 10 < p_ID < 25 and 5 < p_ID < 500 GeV. (eps file)

Momentum difference minus Eloss



Major updates:
-- DomiziaOrestano - 09 Mar 2009 -- DomiziaOrestano - 27-Jan-2010

Responsible: DaveCharlton
Last reviewed by: Never reviewed

Topic attachments
I Attachment History Action Size Date Who Comment
Unknown file formateps Diff_MomentumBottom.eps r2 r1 manage 13.9 K 2009-03-12 - 16:06 DomiziaOrestano eps version of Diff_MomentumBottom plot
PNGpng Diff_MomentumBottom.png r2 r1 manage 45.7 K 2009-03-12 - 16:09 DomiziaOrestano Difference between the Pt measured for the inner detector track and for the muon spectrometer one, tracks in the bottom part of the detector, cosmics data 2008, first Tier1 reprocessing
Unknown file formateps Diff_d0.eps r2 r1 manage 17.6 K 2009-03-12 - 16:09 DomiziaOrestano eps version of Diff_d0 plot
PNGpng Diff_d0.png r2 r1 manage 52.9 K 2009-03-12 - 16:11 DomiziaOrestano Difference between the d0 parameter measured for the muon spectrometer track and for the inner detector one, cosmics data 2008, first Tier1 reprocessing
Unknown file formateps Diff_phi0.eps r2 r1 manage 17.8 K 2009-03-12 - 16:11 DomiziaOrestano eps version of Diff_phi0 plot
PNGpng Diff_phi0.png r2 r1 manage 52.0 K 2009-03-12 - 16:12 DomiziaOrestano Difference between the Phi0 parameter measured for the muon spectrometer track and for the inner detector one, cosmics data 2008, first Tier1 reprocessing
Unknown file formateps Diff_theta0.eps r2 r1 manage 15.0 K 2009-03-12 - 16:13 DomiziaOrestano eps version of Diff_theta0 plot
PNGpng Diff_theta0.png r2 r1 manage 44.6 K 2009-03-12 - 16:13 DomiziaOrestano Difference between the Theta parameter measured for the muon spectrometer track and for the inner detector one, cosmics data 2008, first Tier1 reprocessing
Unknown file formateps Diff_z0.eps r2 r1 manage 15.2 K 2009-03-12 - 16:14 DomiziaOrestano eps version of Diff_z0 plot
PNGpng Diff_z0.png r2 r1 manage 48.2 K 2009-03-12 - 16:19 DomiziaOrestano Difference between the z0 parameter measured for the muon spectrometer track and for the inner detector one, cosmics data 2008, first Tier1 reprocessing
Unknown file formateps Phi0.eps r2 r1 manage 32.2 K 2009-03-09 - 10:40 DomiziaOrestano eps version of Phi0 plot
PNGpng Phi0.png r2 r1 manage 60.1 K 2009-03-09 - 10:04 DomiziaOrestano Correlation between Phi measured in muon spectrometer and in inner detector, cosmics data 2008, first Tier1 reprocessing
Unknown file formateps Theta0.eps r2 r1 manage 29.7 K 2009-03-09 - 10:42 DomiziaOrestano eps version of Theta0 plot
PNGpng Theta0.png r2 r1 manage 45.3 K 2009-03-09 - 10:06 DomiziaOrestano Correlation between Theta measured in muon spectrometer and in inner detector, cosmics data 2008, first Tier1 reprocessing
Edit | Attach | Watch | Print version | History: r7 < r6 < r5 < r4 < r3 | Backlinks | Raw View | WYSIWYG | More topic actions
Topic revision: r7 - 2010-12-06 - PatrickJussel
 
    • Cern Search Icon Cern Search
    • TWiki Search Icon TWiki Search
    • Google Search Icon Google Search

    Atlas All webs login

This site is powered by the TWiki collaboration platform Powered by PerlCopyright &© 2008-2024 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
or Ideas, requests, problems regarding TWiki? use Discourse or Send feedback