next up previous contents index
Next: Electron identification: Bank EIDT Up: ``Track'' related detector data Previous: Charged-particle identification: Bank FRID   Contents   Index


dE/dx data: Bank TEXS

Note: These functions return uncalibrated numbers. In general, dE/dx information should be accessed with subroutines QDEDX and QDEDXM (see 12.1).

XTEX (I)
.TRUE. if dE/dx is available for track I
KNTEX (I)
Number of TPC sectors on track I
In the following, N is the loop index of: DO 10 N = 1, KNTEX(I)
KTEXSI (I,N)
Sector slot number
QTEXTM (I,N)
Truncated Mean of dE/dx measurements
QTEXTL (I,N)
Useful Track Length for dE/dx
KTEXNS (I,N)
Number of Samples used for dE/dx
QTEXAD (I,N)
Average Drift length of samples



Joel Closier
2000-02-07