Option | Meaning | Default |
---|---|---|
ABORT-100 |
Kills an avalanche at size 100 | No |
ABORT-1000 |
Kills an avalanche at size 1000 | No |
ABORT-10000 |
Kills an avalanche at size 10000 | No |
ATTACHMENT |
Include attachment | If data present |
CROSS-INDUCED |
Requests cross induced signals | Yes |
DIRECT |
Computes only direct signals | No |
ELECTRON-PULSE |
Add signals due to electrons | No |
NOATTACHMENT |
Don't include attachment | If data absent |
NOELECTRON-PULSE |
Do not compute electron signals | Yes |
NOPLOT-ELECTRON |
Don't plot electron drift-lines | Yes |
NOPLOT-ION |
Don't plot ion drift-lines | Yes |
NOTOWNSEND |
Don't include multiplication | If data absent |
PLOT-ELECTRON |
Plot electron drift-lines | No |
PLOT-ION |
Plot ion drift-lines | No |
TOWNSEND |
Include multiplication | If data present |
The TOWNSEND and ATTACHMENT options can only be selected if the corresponding data has been entered in the gas section.
See the CROSS-INDUCED option of the SIGNAL command for the distinction between direct and cross induced signals.
A plot frame (e.g. with PLOT_DRIFT_AREA) has to be opened before the call to AVALANCHE_SIGNAL if you wish to use the PLOT-ELECTRON or PLOT-ION options.
Formatted on 21/01/18 at 16:55.