Overview
Next: Input Output
Up: Data Cards
Previous: Data Cards
File definitions
- FILI defines the event input file (see 3.2)
- FILO defines the standard output file POT
(Production Output Tape) (see 3.2)
- MONI writes MONI file for event reconstruction (see
4.3)
monitoring (Vax only)
- SUMR writes SUMR file (see 4.3)
for run reconstruction summary (Vax only)
- FDBA defines an alternate version of the data-base
to be used (see 3.2)
- HIST defines a PAW display file (see 3.3.1)
Dealing with BOS banks
- ADDD adds banks from the output stream (see 3.2)
- REMD removes banks from the output stream (see 3.2)
- REMI will remove banks from the input file before processing
- UDAF uses constants banks from tape rather than data-base
- COMP selects data compression. JULIA default is to compress
integers only.
- NGAR do NOT perform BOS garbage
collection between program modules
- JCAR saves an image of data cards used for processing in
JCAR run header bank (see 4.3)
Run/event selection
- SEVT Selects run and event numbers to be processed (see
3.4)
- SRUN Selects runs to be processed (see 3.4)
- IRUN Defines runs to be ignored (see 3.4)
- NEVT Defines number (or range) of events
to be processed (see 3.4)
Printing
- HPRI Prints HBOOK histograms at end of job (see 3.3.1)
- ERRP defines the number of times any single error is printed
(see 3.3.1)
- DEBU selects events to be debugged (see 3.3.1)
Steering
- PROC defines which JULIA module (process) to be run (see 3.5)
- REPR Selects POT to POT re-processing mode (see 4.2)
- PAS0 Selects PASS 0 running mode (see 4.1)
Special reconstruction options
- FIEL defines central value of ALEPH magnetic
field (override value from tape)
- T0GL defines TPC Tzero (normally taken from database)
- PASC defines PASS0 running conditions
(normally taken from database) (see 4.1)
- TCLK defines TPC clock period (normally taken from tape)
- TDRP drops TPC sectors from reconstruction
- TOPT selects special options for TPC reconstruction
- INOZ disables z-reconstruction in ITC
- IMAT enables additional ITC-TPC track matching after pattern
- SCAU calibrates SATR x vs t
- JTOF disables jet finding in energy-flow
- MCUT override default cuts for muon reconstruction
- NESC do NOT use platines for ECAL module calibration
- NEWT do NOT eliminate ECAL towers if wire signal of module
below threshold
- NGAM do NOT perform GAMPE(C,Q,X) photons reconstruction
- NSCA do NOT apply calibration constants to SiCAL data
- BPOS writes beam position bank (ALPB)
on separate file (see 4.3)
- VREC performs VDET tracking even if too few tracks in event
- etc...
Next: Input Output
Up: Data Cards
Previous: Data Cards
Eric Lancon
Thu Sep 29 15:07:07 MET 1994